D-UN-DY-23 Exam Questions 2026 – Practice Test with Answers

Home / Dell Technologies / D-UN-DY-23

Latest D-UN-DY-23 Exam Practice Questions

The practice questions for D-UN-DY-23 exam was last updated on 2026-11-21 .

Viewing page 1 out of 30 pages.

Viewing questions 1 out of 151 questions.

Question#1

What unity feature supports provisioning within vCenter, provides full visibility to physical storage, and ureases management efficiency?

A. VSI
B. ODX
C. ESI
D. VAAI

Question#2

From the Management section of the Unisphere Settings window, which system setting is configurable?

A. Enable UNIX directory services
B. Pause FAST VP data relocation
C. Enable NTP synchronization
D. Configure email alerts and SMTP

Question#3

Quality of Service is available on which systems?

A. Physical Unity systems only
B. UnityVSA systems only
C. Physical Unity and UnityVSA systems
D. All Flash Unity systems only

Question#4

A user is having difficulty troubleshooting a Unity storage system and the service provider has been contacted for assistance. The service provider needs to run some service commands on the Storage Processors to troubleshoot the issue further.
To allow the service provider remote access to the storage system, which step must be taken?

A. On the storage system, enable SSH
B. For remote access, set the Unisphre preferences to "Optimize".
C. Specify the SMTP configuration
D. Specify the Remote Logging configuration

Question#5

A storage administrator configured a hybrid Unity XT storage system using one default pool containing only drives of the performance tier. They need to expand the Unity with Flash as well as NL-SAS drives and make use of FAST VP using all three tiers. The FAST VP license is already installed.
What is the correct way of adding and configuring the pool(s)?

A. Create a new heterogeneous pool that contains one or more RAID Groups of NL-SAS and flash drives Move the existing LUNs to the new pool Delete the first pool and add to the new pool the available Flash drives
B. To the existing pool, add one or more RAID Groups of NL-SAS and Flash drives
C. Convert the homogeneous pool into a heterogeneous pool To the converted pool, add one or more RAID Groups of NL-SAS and Flash drives
D. To a new, second pool, add one or more RAID Groups of NL-SAS drives To a new, third pool, add one or more RAID Groups of flash drives

Disclaimer

This page is for educational and exam preparation reference only. It is not affiliated with Dell Technologies, Dell Storage, or the official exam provider. Candidates should refer to official documentation and training for authoritative information.

Exam Code: D-UN-DY-23Q & A:  467  Q&As Updated:  2026-11-21

  Get All D-UN-DY-23 Q&As